PhotonIcs and Electromagnetics Research Symposium,
also known as Progress In Electromagnetics Research Symposium
PIERS Proceedings
Published: 2015-07-09
Phased Arrays Pre-treatment Evaluation in Antitumoral Hyperthermia
By
Proceedings of 2015 Photonics & Electromagnetics Research Symposium, Prague, July 6 - 9,Page(s)2602-2607
Abstract
There is general consensus that quality of hyperthermia treatment is a key factor for clinical effectiveness. The optimal treatment is defined by efficient tumor heating without patient discomfort by hot spots. Two optimization methods with the constraint on amplifier nominal power are presented. A voxel-based numerical analysis is performed for 8 dipoles on two rings, positioned around a head/neck volume within a distilled-water bolus. The optimization methods are compared on the basis of the maximal absolute power delivered to the target and other previously defined parameters.
Citation
Fernando Bardati, and Piero Tognolatti, "Phased Arrays Pre-treatment Evaluation in Antitumoral Hyperthermia," Proceedings of 2015 Photonics & Electromagnetics Research Symposium, Prague, July 6 - 9,Page(s)2602-2607
References

1. Gellermann, Johanna, Peter Wust, Dether Stalling, Martin Seebass, Jacek Nadobny, Rudolf Beck, Hans-Christian Hege, Peter Deuflhard, and Roland Felix, "Clinical evaluation and verification of the hyperthermia treatment planning system hyperplan," International Journal of Radiation Oncology Biology Physics, Vol. 47, No. 4, 1145–1156, 2000.
doi:10.1016/s0360-3016(00)00425-9        Google Scholar

2. Sreenivasa, Geetha, Johanna Gellermann, Beate Rau, Jacek Nadobny, Peter Schlag, Peter Deuflhard, Roland Felix, and Peter Wust, "Clinical use of the hyperthermia treatment planning system HyperPlan to predict effectiveness and toxicity," International Journal of Radiation Oncology Biology Physics, Vol. 55, No. 2, 407–419, February 2003.
doi:10.1016/s0360-3016(02)04144-5        Google Scholar

3. Van Haaren, P. M. A., H. P. KoThk, C. A. T. Van den Berg, Z. V. S. V. PJ, S. Oldenborg,L. J. Stalpers, M. S. Schilthuis, A. A. C. De Leeuw, and J. Crezee, "On verification of hyperthermia treatment planning for cervical carcinoma patients," Int. J. Hyperthermia, Vol. 23, 303-314, 2007.        Google Scholar

4. Franckena, Martine, Richard Canters, F. Termorshuizen, Jacoba Van Der Zee, and Gerard Van Rhoon, "Clinical implementation of hyperthermia treatment planning guided steering: A cross over trial to assess its current contribution to treatment quality," International Journal of Hyperthermia, Vol. 26, No. 2, 145–157, 2010.
doi:10.3109/02656730903453538        Google Scholar

5. Kok, H. Petra, Silvia Ciampa, Rianne de Kroon-Oldenhof, Eva J. Steggerda-Carvalho, Gerard van Stam, Paul J. Zum Vörde Sive Vörding, Lukas J. A. Stalpers, Elisabeth D. Geijsen, Fernando Bardati, Arjan Bel, and Johannes Crezee, "Toward online adaptive hyperthermia treatment planning: Correlation between measured and simulated specific absorption rate changes caused by phase steering in patients," International Journal of Radiation Oncology Biology Physics, Vol. 90, 438–445, 2014.
doi:10.1016/j.ijrobp.2014.05.1307        Google Scholar

6. Turner, P. F. and T. Shaefermeyer, "BSD-2000 approach for deep local and regional hyperthermia: Clinical utility," Stahlenther Onkol., Vol. 165, 700-704, 1989.        Google Scholar

7. Van Dijk, Jan D. P., Christoph Schneider, Rob van Os, Leo E. C. M. Blank, and Dionisio G. Gonzalez, "Results of deep body hyperthermia with large waveguide radiators," Adv. Exp. Med. Biol., Vol. 267, 315–319, 1990.
doi:10.1007/978-1-4684-5766-7_31        Google Scholar

8. Crezee, J., H. P. Kok, J. Wiersma, G. van Stam, J. Sijbrands, A. Bel, et al., "Improving locoregional hyperthermia equipment using 3-D power control: From AMC-4 to AMC-8," Graz: Proc 22nd Annual Meeting of ESHO, 14-15, 2005.        Google Scholar

9. Nadobny, Jacek, W. Wlodarczyk, L. Westhoff, and J. Gellermann, "Development and evaluation of a three‐dimensional hyperthermia applicator with water‐coated antennas (WACOA)," Medical Physics, Vol. 30, 2052–2064, 2003.
doi:10.1118/1.1589611        Google Scholar

10. Paulides, M. M., J. F. Bakker, E. Neufeld, J. van der Zee, P. P. Jansen, P. C. Levendag, and G. C. van Rhoon, "The HYPERcollar: A novel applicator for hyperthermia in the head and neck," International Journal of Hyperthermia, Vol. 23, No. 7, 567–576, 2007.
doi:10.1080/02656730701670478        Google Scholar

11. Canters, R.A.M., P. Wust, J. F. Bakker, and G. C. Van Rhoon, "A literature survey on indicators for characterisation and optimisation of SAR distributions in deep hyperthermia, a plea for standardisation," International Journal of Hyperthermia, Vol. 25, No. 7, 593–608, 2009.
doi:10.3109/02656730903110539        Google Scholar

12. Wiersma, J., N. van Wieringen, H. Crezee, and J. D. P. van Dijk, "Delineation of potential hot spots for hyperthermia treatment planning optimisation," International Journal of Hyperthermia, Vol. 23, No. 3, 287–301, 2007.
doi:10.1080/02656730701218914        Google Scholar

13. Bardati, Fernando and Piero Tognolatti, "A voxel-based approach in phased-array optimization for microwave hyperthermia," 44th European Microwave Conference (EuMC), 786–789, 2014.
doi:10.1109/eumc.2014.6986552        Google Scholar

14. Bardati, Fernando and Piero Tognolatti, "Figures of merit and their bounds in radiofrequency heating by phased arrays," International Journal of Hyperthermia, Vol. 29, No. 7, 567–576, 2013.
doi:10.3109/02656736.2013.784813        Google Scholar