PhotonIcs and Electromagnetics Research Symposium,
also known as Progress In Electromagnetics Research Symposium
PIERS Proceedings
Published: 2015-07-09
Evaluation of Electromagnetic Interference Emitted from Compact Fluorescent Lamps According to CISPR-15
By
Proceedings of 2015 Photonics & Electromagnetics Research Symposium, Prague, July 6 - 9,Page(s)1133-1136
Abstract
In this study, Electromagnetic interference (EMI) emitted by the compact fluores- cent lamps (CFL) having biggest pie in the market has been investigated according to CISPR-15. Emissions of CFLs vary depending on trademark, since some cannot provide the requirements of CISPR-15 standards such that they act as contaminants in the electric supply system. Con- ducted analysis considering the limits of CISPR-15 at 150–500 kHz frequency brings out that the effect of CFL produced by Company A at 181.298 kHz is 83.94 dBµV, whereas the effect of CFL produced by Company D at 173.593 kHz frequency is 49,92 dBµV, respectively. Obtained results are out of CISPR-15 limits of 66–56 dBµV.
Citation
Selçuk Helhel, Sukru Ozen, Mehmet Cakir, Atalay Kocakusak, and Samet Yalcin, "Evaluation of Electromagnetic Interference Emitted from Compact Fluorescent Lamps According to CISPR-15," Proceedings of 2015 Photonics & Electromagnetics Research Symposium, Prague, July 6 - 9,Page(s)1133-1136
References