Proceedings of 2015 Photonics & Electromagnetics Research Symposium, Prague, July 6 - 9,Page(s)2079-2084
Abstract
Various studies on specific absorption rates (SARs) have been carried out with
liquid phantoms representing human body tissues in the field of electromagnetic compatibility
(EMC) research. As a faithful representation of human body tissue is needed to establish an
accurate SAR for measurement, knowledge regarding the precise measurement of sample materials
with high permittivity and high loss is very important. In this study, the complex permittivity
of a liquid phantom material was measured using the open-ended cut-off circular waveguide
reflection method. The effectiveness of the proposed approach for measuring a liquid phantom
with high permittivity and high loss was also confirmed by comparing the measurement results
with those obtained using the TM010 circular cavity resonator method.
Citation
Kouji Shibata,
"Broadband Measurement of Complex Permittivity for Liquids Using the Open-ended Cut-off Circular Waveguide Reflection Method," Proceedings of 2015 Photonics & Electromagnetics Research Symposium, Prague, July 6 - 9,Page(s)2079-2084