Oversensing and Undersensing of Implantable Cardiac Medical Devices Exposed to EMI
By
Proceedings of 2015 Photonics & Electromagnetics Research Symposium, Prague, July 6 - 9,Page(s)1905-1908
Abstract
Oversensing and undersensing issues of Implantable Cardiac Medical Devices (ICM- Ds) are addressed in this paper. Particularly, an extensive experimental study has been performed in order to highlight that EMI affects ICMD sensing performances in correspondence of specific heartbeat status in terms of both frequency and amplitude. Experiments have been carried out on both a Pacemaker and an Implantable Cardioverter Defibrillator within an anechoic chamber. This guarantees a proper EMI injection, whose frequency has been chosen in accordance with ANSI/AAMI ISO 14117: standard 2012. In addition, such an environment also guarantees and appropriate shielding against external EMI sources, thus ensuring the reliability of the tests.
Citation
Gianluca Gatto, Ignazio Marongiu, Alessandro Serpi, Ivan Luigi Spano, and M. Tomasi, "Oversensing and Undersensing of Implantable Cardiac Medical Devices Exposed to EMI," Proceedings of 2015 Photonics & Electromagnetics Research Symposium, Prague, July 6 - 9,Page(s)1905-1908
References

1. Ott, H. W., Electromagnetic Compatibility Engineering, Wiley, USA, 2009.        Google Scholar

2. Al-Ahmad, A., K. A. Ellenbogen, A. Natale, and P. J. Wang, Pacemaker and Implantable Cardioventer Defibrillators, Cardiotext Publishing, USA, 2010.        Google Scholar

3. Spano, I. L., S. Sulis, A. Serpi, I. Marongiu, and G. Gatto, "EMC characterization of implantable cardiac medical devices in an anechoic chamber," Proc. IEEE International Symposium on Electromagnetic Compatibility (EMC-Europe 2014), 6, Gothenburg, Sweden, September 1-4, 2014.
doi:10.1109/emceurope.2014.6931026        Google Scholar

4. Spano, I. L., A. Serpi, A. Fanti, V. Nissardi, A. Lai, V. Caredda, P. F. Orrù, G. Mazzarella, I. Marongiu, and G. Gatto, "Electromagnetic compatibility analysis of RFID and implantable medical devices," Proc. IEEE Telecommunication Forum (TELFOR 2014), 4, Belgrade, Serbia & Montenegro, November 25-27, 2014.
doi:10.1109/telfor.2014.7034532        Google Scholar

5. "Electromagnetic compatibility (EMC) --- Part 4-3 Testing and measurement techniques --- Radiated, radio-frequency, electromagnetic field immunity test," IEC 61000-4-3, 2008.        Google Scholar

6. "Active implantable medical devices --- Part 2 Particular requirements for active implantable medical devices intended to treat bradyarrhythmia (cardiac pacemakers)," CEI EN 45502-2-1, 2005.        Google Scholar

7. "Active implantable medical device --- Electromagnetic compatibility --- EMC test protocols for implantable cardiac pacemakers and implantable defibrillators," AAMI Standard PC69, 2007.        Google Scholar

8. Irnich, W., "Electronic security systems and active implantable medical devices," Pacing Clin. Electrophysiol., Vol. 25, No. 8, 1235-1258, 2002.
doi:10.1046/j.1460-9592.2002.01235.x        Google Scholar