Electron Beam Detection by Induced Resonance in Cylindrical Cavity
By
Proceedings of 2015 Photonics & Electromagnetics Research Symposium, Prague, July 6 - 9,Page(s)896-901
Abstract
An investigation on the power energy injection in a resonator by electron stream is reported in this paper, by documenting the power transfer from an electron beam to a resonant cavity, coupled to an external circuitry. The proposed system has been employed to measure the radiation dose deposed by a medical electron linear accelerator. A prototype has been fabricated and tested through VNA cold measurements and dose deposition measurements. A microcon- troller system has been employed to obtain a digital output, the Monitor Units. The linearity of the Monitor Units for different values of accumulated dose, have allowed to employ this system for the real time dose measurements.
Citation
Franco Di Paolo, Alessia Ciccotelli, Silvia De Stefano, Giuseppe Felici, Alberto Leggieri, Filippo Marangoni, and Davide Passi, "Electron Beam Detection by Induced Resonance in Cylindrical Cavity," Proceedings of 2015 Photonics & Electromagnetics Research Symposium, Prague, July 6 - 9,Page(s)896-901
References

1. International Standard EN 60601-2-1, Medical Electrical Equipment --- Part 2-1: Particular Requirements for the Basic Safety and Essential Performance of Electron Accelerators in the Range 1 MeV to 50 MeV, 3rd Ed., International Electrotechnical Commission, 2009.        Google Scholar

2. Turner, A. P., "Regulations, standards and guidelines for the use of medical electron linear accelerators," IEEE Transactions on Nuclear Science, Vol. 26, No. 1, 1979.
doi:10.1109/tns.1979.4330448        Google Scholar

3. Uvarov, V. L., et al. "A beam monitoring and calibration system for high-power electron LINACs," Proceedings of the Particle Accelerator Conference, Vancouver, BC, 1997.
doi:10.1109/pac.1997.751165        Google Scholar

4. Ruf, M., S. Muller, S. Setzer, and L. P. Schmidt, "Beam position and energy monitoring in compact linear accelerators for radiotherapy," IEEE Transactions on Biomedical Engineering, Vol. 61, No. 2, 2014.
doi:10.1109/tbme.2013.2279793        Google Scholar

5. Rosenzweig, J. B., Accelerator Technology II: Waveguides and Cavities, 183-193, Fundamentals of Beam Physics, Oxford University Press, Oxford, 2003.        Google Scholar

6. Goldberg, D. A. and G. R. Lambertson, "Dynamic devices a primer on pickups and kickers,", 540-561, 1992.        Google Scholar

7. Ramo, S., J. R. Whinnery, and T. Van Duzer, "Resonant cavities," Fields and Waves in Communication Electronics, 3rd Edition, 303-310, 699-701, 719-723, John Wiley & Sons, New York, 1994.        Google Scholar

8. Leggieri, A., D. Passi, G. Felici, S. De Stefano, and F. Di Paolo, "Magnetron high power system design," International Journal of Simulation System Science and Technology, Vol. 16, 2015.
doi:10.5013/ijssst.a.16.01.03        Google Scholar

9. Di Paolo, F., "Resonant elements," Networks and Devices Using Planar Transmission Lines, 505-512, CRC Press LLC, 2000.        Google Scholar

10. S.I.T. S.p.A., LIAC-S product description, Italy, 2013, Available: http://soiort.com.

11. IAEA TRS 398, "Absorbed dose determination in external beam radiotherapy: An international code of practice for dosimetry based on standards of absorbed dose to water," Vienna, December 2000.        Google Scholar

12. PTW Freiburg GmbH, Mephysto Software Suite product description, Germany, 2012, Available: http://www.ptw.de/2082.html.